TRA | Model TRA load cell measure the torque of continuous rotatin object. Platinum coated connector provides long term signal stability and high accuracy. These models are most appropriate for industrial measurement. Applications Include the performance tester for automotive components such as clutchs transmissions motors and pumps. * Option : r.p.m. sensor Foot mount. | | |
| |
|
|
Specifications | Accuracy | Rated capacity(R.C) | 1~300㎏f-m (9.807N-m~2.942kNm) | Rated output(R.O) | 1.5mV/V±1%(1~5㎏f-m:1mV/V) | Nonlinearity | 0.3%R.O | Hysteresis | 0.2%R.O | Reperatability | 0.3%R.O. | Excitation recommended | 10V | Terminal resistance | 350 Ω ±1% | Insulation resistance bridge | 200 MΩ | Temperature effect on rated output | 0.3% R.O./10 C | Temperature effect on zero balance | 0.2% Load/10 C | Safe overload | 120% R.C. | Cable length | φ7.4 core cable 3m | | |
|
Model | Capacity | A | B | C | D | E | F | φG | φH | J | K | L | M | N | P | Q | R | Weight (kg) | TRA-1K | 1kgf-m (9.807N-m) | 203 | 43 | 117 | 38 | 5 | 35 | 18 | 85 | 90 | 50 | 7 | 17 | 7 | M6 | 15 | 5x5 | 3 | TRA-2K | 2kgf-m (19.61N-m) | 203 | 43 | 117 | 38 | 5 | 35 | 18 | 85 | 90 | 50 | 7 | 17 | 7 | M6 | 15 | 5x5 | TRA-5K | 5kgf-m (49.03N-m) | 203 | 43 | 117 | 38 | 5 | 35 | 18 | 85 | 90 | 50 | 7 | 17 | 7 | M6 | 15 | 5x5 | TRA-10K | 10kgf-m (98.07N-m) | 240 | 55 | 130 | 50 | 5 | 45 | 32 | 100 | 90 | 50 | 7 | 17 | 7 | M6 | 15 | 10x8 | 7 | TRA-20K | 20kgf-m (196.1N-m) | 240 | 55 | 130 | 50 | 5 | 45 | 32 | 100 | 90 | 50 | 7 | 17 | 7 | M6 | 15 | 10x8 | TRA-50K | 50kgf-m (490.3N-m) | 340 | 95 | 150 | 90 | 5 | 85 | 47 | 118 | 100 | 60 | 8 | 20 | 9 | M8 | 17 | 12x8 | 12 | TRA-100K | 100kgf-m (980.7N-m) | 340 | 95 | 150 | 90 | 5 | 85 | 47 | 118 | 100 | 60 | 8 | 20 | 9 | M8 | 17 | 12x8 | TRA-200K | 200kgf-m (1.961KN-m) | 360 | 103 | 154 | 100 | 3 | 95 | 63 | 135 | 100 | 60 | 8 | 20 | 9 | M8 | 17 | 18x11 | 23 | TRA-300K | 300kgf-m (2.942KN-m) | 360 | 103 | 154 | 100 | 3 | 95 | 63 | 135 | 100 | 60 | 8 | 20 | 9 | M8 | 17 | 18x11 | | |