| Specifications | Accuracy |
| CLG | CLH |
| Rated capacity(R.C) | 500kgf 1tf 2tf 5tf 10tf 20tf 50tf 100tf 200tf 300tf 500tf | 500kgf 1tf 2tf 5tf 10tf 20tf 50tf |
| Rated output(R.O) | 2mV/V±0.1% | 2mV/V±0.1% |
| Nonlinearity | 0.05% of R.O.(100tf 200tf : 0.1%) | 0.02% of R.O. |
| Hysteresis | 0.05% of R.O.(100tf 200tf : 0.1%) | 0.02% of R.O. |
| Repeatability | 0.03% of R.O.(100tf 200tf : 0.05%) | 0.02% of R.O. |
| Zero balance | ±2% of R.O. | ±2% of R.O. |
| Temperature effect on rated output | 0.05% of LOAD/10℃ | 0.03% of LOAD/10℃ |
| Temperature effect on zero balance | 0.05% of R.O./10℃ | 0.03% of R.O./10℃ |
| Temperature range compensated | -10~60℃ |
| Temperature range safe | -10~70℃ |
| Terminal resistance input | 350 ±30Ω |
| Terminal resistance output | 350 ±30Ω |
| Insulation resistance bridge/case | 2000MΩ |
| Excitation recommended | 10V |
| Safe overload | 150% R.C |
| Cable length | Φ7mm 4core3m |