Specifications | Accuracy |
CLG | CLH |
Rated capacity(R.C) | 500kgf 1tf 2tf 5tf 10tf 20tf 50tf 100tf 200tf 300tf 500tf | 500kgf 1tf 2tf 5tf 10tf 20tf 50tf |
Rated output(R.O) | 2mV/V±0.1% | 2mV/V±0.1% |
Nonlinearity | 0.05% of R.O.(100tf 200tf : 0.1%) | 0.02% of R.O. |
Hysteresis | 0.05% of R.O.(100tf 200tf : 0.1%) | 0.02% of R.O. |
Repeatability | 0.03% of R.O.(100tf 200tf : 0.05%) | 0.02% of R.O. |
Zero balance | ±2% of R.O. | ±2% of R.O. |
Temperature effect on rated output | 0.05% of LOAD/10℃ | 0.03% of LOAD/10℃ |
Temperature effect on zero balance | 0.05% of R.O./10℃ | 0.03% of R.O./10℃ |
Temperature range compensated | -10~60℃ |
Temperature range safe | -10~70℃ |
Terminal resistance input | 350 ±30Ω |
Terminal resistance output | 350 ±30Ω |
Insulation resistance bridge/case | 2000MΩ |
Excitation recommended | 10V |
Safe overload | 150% R.C |
Cable length | Φ7mm 4core3m |